| All data is for information only------(<---links) | |
|---|---|
| PRODUCT DATA of AISI 304 | 
| Material | AISI 304 | 
| Product Datasheet | AK steel 304_304L_Data_Sheet | 
| General Information | General purpose austenitic grade for enhanced corrosion resistance | 
| Effects of Space environment | The natural oxide layer is not repaired in vacuum when damaged. Cold welding might occur in contact to similar materials. | 
| Chemical Composition | 8 to 12% Ni, 18 to 20% Cr, 2% Mn max, 1% Si max, 0.15% C max, Rem. Fe | 
| Name of Manufacturer | many suppliers | 
| EXPERIENCE IN PRACTICE | 
|---|
| Development Status | Commercial Product | 
| Cost Range | Low | 
| Lot Reproducibility | Good | 
| Equivalent Designations | A2; A2-50; A2-70; A2-80 | 
| Space Experience | Good | 
| PHYSICAL PROPERTIES | 
|---|
| Crystal Structure | Face centered cubic (fcc) | 
| Specific Gravity | 7.95 | 
| Magnetic Properties | Nonmagnetic | 
| ELASTIC PROPERTIES | 
|---|
| Tensile Modulus | 193 to 200 GPa | 
| RELEVANT PROPERTIES FOR USE IN SPACE COMMUNITY | 
|---|
| General Corrosion Status | No specific corrosion protection required | 
| Stress Corrosion Status | High Resistance to SCC: Table 1 Remark: acc. to ECSS-Q-ST-70-36C Data Quality: Design Data | 
| EMF vs SCE | -0.1 V Remark: Measured in 3.5% NaCl solution Data Quality: Design Data | 
| Bimetallic Corrosion | Can be connected without any restriction to:  Cr, Au, Pt, C, Rh, Ag, Gun-metal, P-bronzes, Sn-bronzes, Ti+alloys Can be connected in a non-controlled environment to the above and Cd, Cu, Brasses, Ni, monel, inconel, N-Mo alloys, 400 series stainless steel Can be connected in a clean room environment to above and Al-Cu alloys, Cu-Ni alloys, Al-bronzes, Si-bronzes Needs specific measures: All others Test:ECSS-Q-ST-70C Rev.1 Table 5.1 Data Quality: Design Data | 
| FLUID SYSTEMS COMPATIBILITY | 
|---|
| Gaseous Oxygen (GOX) | Meets the mechanical impact requirements. No batch test required. | 
| Liquid Oxygen (LOX) | Meets the mechanical impact requirements. No batch test required. | 
| Nitrogen Tetroxide (N2O4) | SCC susceptibility is low and no fluid decomposition | 
| Hydrazine (HDZE) | SCC susceptibility is low and no fluid decomposition |