| Data still to be completed------(<---links) | |
|---|---|
| PRODUCT DATA of A286 | 
| Material | A286 | 
| General Information | This super alloy is can be used at temperatures up to 700 C. Its main uses are highly loaded fasteners | 
| Chemical Composition | 25% Ni, 15% Cr, 2% Ti, 1.5% Mn, 1.3% Mo, 0.3% V, Rem. Fe | 
| Name of Manufacturer | Boehler Edelstahl GMBH & Co KG Mariazeller Straße 25, A-8605 Kapfenberg, Austria +43-3862/20-7181 +43 3862/20-7576 info@bohler-edelstahl.com www.bohler-edelstahl.com Maher Ltd Edward Street, Sheffield S3 7GD, UK +44 (0)114 290 9200 +44 (0)114 290 9290 www.maher.co.uk | 
| EXPERIENCE IN PRACTICE | 
|---|
| Development Status | Commercial Product | 
| Cost Range | Medium | 
| Equivalent Designations | Werk. No. 1.4980, Z6 NCT 25/15, UNS S66286, AISI 660, Z3NCT25, A 286 | 
| Space Experience | Extensive | 
| PHYSICAL PROPERTIES | 
|---|
| Specific Gravity | 7.92 @RT | 
| Phase changes | Precipitation of Ni3Ti occures between 650 and 815 C | 
| Magnetic Properties | Nonmagnetic | 
| ELASTIC PROPERTIES | 
|---|
| Tensile Modulus | 201 GPa | 
| Shear Modulus | 71.7 GPa | 
| Poisson Ratio | 0.306 | 
| ELECTRICAL PROPERTIES | 
|---|
| Electrical Volume Resistivity | 9.1e-7 ohm.m | 
| THERMAL PROPERTIES | 
|---|
| Thermal Conductivity | 13 W/m.K | 
| Thermal Expansion Coefficient | 16.9 μstrain/°C | 
| Melting Range | 1370 to 1430 °C | 
| Specific Heat | 0.461 J/g.K | 
| RELEVANT PROPERTIES FOR USE IN SPACE COMMUNITY | 
|---|
| Corrosion/Thermal | High resistance up to 700°C. | 
| Stress Corrosion Status | High Resistance to SCC: Table 1 Remark: acc. to ECSS-Q-ST-70-36C Data Quality: Design Data | 
| EMF vs SCE | -0.07 V Remark: Measured in 3.5% NaCl solution Data Quality: Design Data | 
| Bimetallic Corrosion | Can be connected without any restriction to:  Cr, Au, Pt, C, Rh, Ag, Gun-metal, P-bronzes, Sn-bronzes, Ti+alloys Can be connected in a non-controlled environment to the above and Cd, Cu, Brasses, Ni, monel, inconel, N-Mo alloys, 400 series stainless steel Can be connected in a clean room environment to above and Al-Cu alloys, Cu-Ni alloys, Al-bronzes, Si-bronzes Needs specific measures: All others Test:ECSS-Q-ST-70C Rev.1 Table 5.1 Data Quality: Design Data | 
| FLUID SYSTEMS COMPATIBILITY | 
|---|
| Gaseous Oxygen (GOX) | Meets the mechanical impact requirements. No batch test required. | 
| Liquid Oxygen (LOX) | Meets the mechanical impact requirements. No batch test required. | 
| Nitrogen Tetroxide (N2O4) | SCC susceptibility is low and no fluid decomposition | 
| Hydrazine (HDZE) | SCC susceptibility is low and no fluid decomposition | 
| SPECIAL RECOMMENDATIONS | 
|---|
| Special Recommendations | Suitable for fasteners. |