All data is for information only------(Home) | |
---|---|
PRODUCT DATA of AISI 304 |
Material | AISI 304 |
Product Datasheet | AK steel 304_304L_Data_Sheet |
General Information | General purpose austenitic grade for enhanced corrosion resistance |
Effects of Space environment | The natural oxide layer is not repaired in vacuum when damaged. Cold welding might occur in contact to similar materials. |
Chemical Composition | 8 to 12% Ni, 18 to 20% Cr, 2% Mn max, 1% Si max, 0.15% C max, Rem. Fe |
Name of Manufacturer | many suppliers |
EXPERIENCE IN PRACTICE |
---|
Development Status | Commercial Product |
Cost Range | Low |
Lot Reproducibility | Good |
Equivalent Designations | A2; A2-50; A2-70; A2-80 |
Space Experience | Good |
PHYSICAL PROPERTIES |
---|
Crystal Structure | Face centered cubic (fcc) |
Specific Gravity | 7.95 |
Magnetic Properties | Nonmagnetic |
ELASTIC PROPERTIES |
---|
Tensile Modulus | 193 to 200 GPa |
RELEVANT PROPERTIES FOR USE IN SPACE COMMUNITY |
---|
General Corrosion Status | No specific corrosion protection required |
Stress Corrosion Status | High Resistance to SCC: Table 1
Remark: acc. to ECSS-Q-ST-70-36C Data Quality: Design Data |
EMF vs SCE | -0.1 V Remark: Measured in 3.5% NaCl solution Data Quality: Design Data |
Bimetallic Corrosion | Can be connected without any restriction to: Cr, Au, Pt, C, Rh, Ag, Gun-metal, P-bronzes, Sn-bronzes, Ti+alloys
Can be connected in a non-controlled environment to the above and Cd, Cu, Brasses, Ni, monel, inconel, N-Mo alloys, 400 series stainless steel Can be connected in a clean room environment to above and Al-Cu alloys, Cu-Ni alloys, Al-bronzes, Si-bronzes Needs specific measures: All others Test:ECSS-Q-ST-70C Rev.1 Table 5.1 Data Quality: Design Data |
FLUID SYSTEMS COMPATIBILITY |
---|
Gaseous Oxygen (GOX) | Meets the mechanical impact requirements. No batch test required. |
Liquid Oxygen (LOX) | Meets the mechanical impact requirements. No batch test required. |
Nitrogen Tetroxide (N2O4) | SCC susceptibility is low and no fluid decomposition |
Hydrazine (HDZE) | SCC susceptibility is low and no fluid decomposition |